Safety valve closing pressure, cracking pressure and discharge pressure

Shut-off pressure, cracking pressure and discharge pressure of safety valve liquid lines Unit: MPa Working pressure of pipeline (gauge) Closing pressure Opening pressure Discharge pressure ≤0.25 -0.03 +0.03 +0.06> 0.25 -0.3 ~ -0.1 + 0.1 ~ +0.3 +0.25 Safety valve Gas pipeline closing pressure, cracking pressure and discharge pressure Gas pipeline unit: MPa Working pressure of pipeline (gauge) Closing pressure Opening pressure Discharge pressure ≤0.25 Normal -0.03 +0.03 +0.045 - High sensitivity -0.025 +0.025 +0.04> 0.25 General -0.1 +0.1 +0.15 - High sensitivity -0.05 +0.05 +0.1 Opening pressure of steam boiler safety valve Steam boiler safety valve Unit: MPa Boiler working pressure (gauge) Safety valve Of the opening pressure Safety valve name <1.3 Working pressure +0.2 Atmospheric pressure control Safety valve working pressure +0.3 Atmospheric pressure Working safety valve 1.3 ~ 6.0 1.03 times Working pressure control Safety valve 1.05 times Working pressure Working safety valve> 0.6 1.03 times Working pressure control 1.08 times the working pressure of the safety valve work safety valve Keywords for the search: more valve product information pipeline pressure (gauge pressure) off the pressure to open the pressure row Pressure ≤0.25 -0.03 +0.03 +0.06> 0.25 -0.3 ~ -0.1 +0.1 ~ +0.3 +0.25 Working pressure of pipeline (gauge) Closing pressure Opening pressure Discharge pressure ≤0.25 Normal -0.03 +0.03 +0.045 - High sensitivity -0.025 +0.025 +0.04> 0.25 General -0.1 +0.1 +0.15 - High sensitivity -0.05 +0.05 +0.1 Boiler working pressure (gauge) Opening pressure of safety valve Safety valve name <1.3 Working pressure +0.2 Atmospheric pressure control Safety valve Working Pressure +0.3 Atmospheric Pressure Working Safety Valve 1.3 ~ 6.0 1.03 Times Working Pressure Control Safety Valve 1.05 Times Working Pressure Working Safety Valve> 0.6 1.03 Times Working Pressure Control Safety Valve 1.08 Times Working Pressure Working Safety Valve

Counter Flow Closed Cooling Tower

Let's look at the comparison of electric energy, electric energy is not different, because they are all through the same power equipment to operate the equipment, the power of the two is similar, the running time is the same, basically the energy consumption is about the same.

To sum up, for the Closed Cooling Tower energy saving accounting can be strong to open the tower out, and, today are advocating energy conservation and environmental protection, this is the general trend, so the closed cooling tower is more and more favored by the majority of users.


Counter Flow Closed Cooling Tower,Closed Type Cooling Tower,Cooling Tower Closed Loop System,Closed Circuit Cooling Tower

Wuxi Ark Fluid Science Technology Co., Ltd. , https://www.fangzhou-arkfluid.com